Air Contrast (Double) BE
📡
View 3 of 4

Decubitus R/L

IMAGE RECEPTOR
Patient position
Begin prone; multiple rotations to coat then air-distend.
Part position
Barium first, then drained; air insufflated for double contrast.
Central ray
Iliac crest; PA axial sigmoid 30–40° caudal to ASIS.
IR placement
35x43 cm.

Tech pearls

  • Double contrast is superior for polyp detection.
  • Right lat decub: air rises to ascending colon.