Quick technique

kVp
70–80
mAs
15–25
SID
40 in
Grid
Yes
Detector
24x30 cm.
Breath
Suspend on expiration.

Views

Tap any card to expand positioning, anatomy & technique inline

IMAGE RECEPTOR
Verified positioning image coming soon

We only show verified diagrams for the correct projection. A licensed asset for this view hasn’t been added yet.

Placeholder
Patient position
Supine on fluoro table; obliques rotated 45°.
Part position
Contrast instilled via Foley catheter to bladder capacity.
Central ray
2 in above symphysis pubis, perpendicular (AP) or 10° caudal.
IR placement
24x30 cm.

TechniqueDefault

kVp
70–80
mAs
15–25
SID
40 in
Grid
Yes
Breath
Suspend on expiration.
Detector
24x30 cm.

Custom values save locally on this device. Cloud sync & department sharing coming soon.

Anatomy coverage

Bladder; UV junctions; check for reflux.

Tech pearls

  • Strict sterile technique with Foley.
  • Watch for vesicoureteral reflux during fill.

Image evaluation

  • Bladder fully distended
  • No extravasation outside bladder wall

Common mistakes

  • Catheter not in bladder → extravasation pattern
  • Not imaging both obliques to clear UVJs