Hand
💪
View 2 of 3

Oblique Hand

IMAGE RECEPTOR+45°
45° oblique with sponge support
Patient position
Seated, from PA externally rotate 45°.
Part position
Fingers separated and parallel to IR on a sponge.
Central ray
Perpendicular to 3rd MCP.

Tech pearls

  • Keep fingers parallel to IR — they should not droop.